Home News Knowledges Inside the CDFU: Cyclonic Separation and Micro-Bubbles Strip Oil Without Chemicals

Inside the CDFU: Cyclonic Separation and Micro-Bubbles Strip Oil Without Chemicals

2026-11-16 14 readings

Removing oil from wastewater usually means chemicals, long residence times or both. The CDFU from SINOKLE takes a different route: it merges centrifugal separation, dissolved gas flotation and ultra-fine bubble generation in one shell, and strips out oil, suspended solids, emulsified oil and other pollutants by physical means alone.

Three steps inside one vessel

  • Cyclonic centrifugal separation. The wastewater enters the unit tangentially and forms a high-speed vortex; centrifugal force drives oil droplets and suspended solids toward the centre of the vortex.
  • Ultra-fine bubble adsorption. An ejector dissolves air into the water, releasing ultra-fine bubbles 5-30 microns in diameter. Their large surface area and slow rise let them contact and attach to the pollutants, building a gas-liquid-solid three-phase mixture.
  • Flotation separation. Carrying their captured pollutants, the bubbles rise to the surface because their density is lower than that of water, forming a scum layer that is removed mechanically. The pollutants leave with the scum; the water stays behind.

The whole sequence needs no chemicals and relies on purely physical demulsification, with a treatment residence time of only 1-5 minutes, markedly better than what conventional flotation processes manage.

Physical demulsification is not just an environmental talking point; it changes the sludge question. Chemical flocculation converts dissolved and emulsified oil into a chemical sludge that must be dewatered and shipped as hazardous waste, and the cost of that disposal routinely rivals the cost of the chemicals themselves. A unit that separates oil by buoyancy instead produces a concentrated scum that can often be recovered or reused, which is why refineries under waste-minimisation pressure keep physical options on the shortlist. It also removes the risk of overdosing chemicals when the feed oil load swings.

The numbers behind the design

Single-stage oil removal exceeds 90% and suspended solids removal exceeds 85%. Treatment efficiency runs 3-8 times that of conventional flotation, while residence time is shortened to less than 5 minutes. The skid-mounted structure shrinks the unit to 1/8-1/3 the volume of conventional flotation equipment, which suits plants short on space. A fully enclosed pressurised design prevents odour leakage and supports remote monitoring and automatic operation, trimming manual intervention and O&M cost. And the unit tolerates harsh feed: high-concentration wastewater with an oil content of up to 20000 ppm passes through, water quality fluctuations included, with emulsified oil and fine suspended solids as its particular strengths.

The engineering details reward a closer look. Dissolving air with an ejector avoids moving parts in the saturation loop, and the 5-30 micron bubble range sits where flotation works best: large enough to rise at a useful speed, small enough to present enough surface to capture fine droplets. The tangential entry that drives the vortex also pre-shears the feed, which helps strip stabilising films off emulsified droplets before the bubbles ever reach them. Both effects show up as higher capture efficiency per unit of gas consumed.

Where it has been deployed

Track records exist across several industries. At a large petrochemical enterprise, CDFU units treat oily wastewater at 200 m³/h; influent oil falling from several thousand mg/L to below a few tens of mg/L, suspended solids dropping substantially at the same time, and the effluent meets the national discharge standard. In oilfield service, a petrochemical enterprise in Xinjiang applies the units to black water: oil content of no more than 20000 ppm comes down to no more than 150 ppm, the water content of the oil after secondary dewatering stays at or below 30%, and corrosion of the injection pipelines is markedly relieved. In electric desalting service, the unit achieves purely physical demulsification, recovers oil clean enough to send straight to refining, and avoids hazardous sludge, an economic and environmental gain at once.

Adoption has followed the results: the technology has been promoted at leading enterprises including Sinopec, PetroChina and CNOOC, extended to landfill leachate and other difficult industrial wastewater, granted 13 patents in total, and become a project supported by the Shenzhen Science and Technology Innovation Commission.

Patent counts are an imperfect proxy, but thirteen granted patents and support from the Shenzhen Science and Technology Innovation Commission indicate a design that has been iterated rather than assembled once. For plant operators the practical takeaway is simpler: the technology has survived contact with refinery, oilfield and desalting duty, and the failure modes of those duties are already engineered into the current generation of units.

Fitting the unit to the job

The design brief is specific rather than universal. It earns its keep where feed oil loads are high and fluctuating, where emulsified droplets defeat gravity separators, where floor space is tight, and where chemical dosing would create sludge disposal problems of its own. Where any of those conditions holds, a physical, fast and compact flotation unit changes the economics of the whole treatment train; where none does, simpler equipment may still suffice.