Coal gasification turns a solid fuel into a gas, and in doing so it produces a scrubbing stream that carries everything the gas was not supposed to keep: tar aerosols, fine char, dissolved organics and a good deal of water chemistry that nothing in a conventional plant was designed for.

The result is a wastewater that is high in oil, high in suspended solids and chemically complicated. Treating it is not a matter of picking the right unit; it is a matter of arranging three units so that each one is given only the job it is good at.

Why scrubbing water resists simple treatment

The solids are fine and partly carbonaceous, so they do not settle at a useful rate and they do not filter well either. The oil is partly emulsified, and the surfactant load from the gas cleaning chemistry keeps it that way. On top of that, the stream carries a gel-like colloidal structure that raises viscosity and slows every mass transfer step downstream, including oxidation.

Any single-stage answer fails on one of those three. Settling removes the coarse fraction and leaves the rest. Filtration blinds quickly. Oxidation reacts with the dissolved fraction but does not remove the particles that carry much of the COD.

Step one: let gravity do the cheap work

The line SINOKLE builds for this stream has three steps, and the first one is deliberately unremarkable.

Scrubbing wastewater enters a collection tank first. Coarse impurities settle, scum floats, and the tank absorbs the flow variation that gasifier operation produces. Nothing sophisticated happens here, and that is the point — the cheapest separation available is the one that uses no equipment at all.

Step two: flotation with bubbles small enough to matter

After demulsifier dosing, the water goes to the CDFU cyclonic dissolved gas flotation unit. CDFU generates large quantities of micro and nano bubbles and uses swirl to bring them into contact with the dispersed phase. Bubbles collide with and attach to oil droplets and fine particles, forming agglomerates with a density lower than water, and the agglomerates rise and are removed as oily sludge.

Bubble size is the whole mechanism. A large bubble rises fast and carries little; a micro bubble rises slowly, has a much higher surface-area-to-volume ratio and attaches preferentially to the fine fraction that gravity settling cannot touch. The oily sludge goes to a sludge tank and the treated water moves on.

Step three: ozone to break the gel, not just the COD

CDOF is the integrated advanced ozone oxidation flotation unit and a patented device in its own right. Its job in this line is deceptively simple: ozone is a strong oxidant, so it decomposes organic matter and lowers both COD and BOD. But the more useful effect on this particular stream is physical. Ozone destroys the colloidal structure and reduces viscosity, which makes everything downstream easier — pumping, filtration, and any biological step that follows.

Inside the unit, ozone is mixed thoroughly with the wastewater rather than bubbled through it casually, so the reaction happens in the liquid rather than in the off-gas. Gel structure breaks, viscosity drops, and the residual organics that flotation could not lift are either oxidised or made separable.

What the three steps deliver together

  • Short flow sheet. Collection tank, CDFU, CDOF, and supporting filtration. Fewer vessels means fewer transfer pumps and fewer places for the emulsion to re-form.
  • Skid-mounted and mobile. The equipment is skid-mounted, easy to transport and install, and can be truck-mounted and operated on site, which suits gasification projects built in stages.
  • Retention time at one fifth of conventional systems. The units are compact, so the tankage that would normally be needed for settling simply is not built.
  • Fully enclosed, fully automatic. No odour release, no manual skimming, and much less operator intervention, which matters because gasification plants rarely have spare qualified staff for a wastewater unit.

Results from a live gasification project

At one coal gasification scrubbing wastewater project, influent carried 2,000 mg/L of oil or less with suspended solids up to 300 mg/L. After the line, effluent oil came out at 500 mg/L or below and suspended solids at 20 mg/L or below. Those figures are not discharge quality, and they are not meant to be: they meet the influent requirement of the downstream supporting process, which is where the remaining load is dealt with.

Framing the target correctly is half the engineering. A treatment line that tries to reach discharge quality in one pass on this stream becomes expensive and unreliable. A line that delivers a predictable feed to the next process, at a retention time one fifth of the conventional alternative, keeps the whole plant stable — and stability is what a gasifier needs from its water side.

Where this arrangement belongs

It fits plants where scrubbing water is one of several streams and where the downstream process can accept the residual load. It does not fit a site that has to meet a direct discharge limit with no polishing step, and it does not replace the need to control tar carry-over at the gasifier itself. What it does is turn an unmanageable stream into a manageable one, in a footprint small enough to fit inside an existing battery limit.