Home News Knowledges Coal Tar Hydrogenation Sour Water: Acidity, Phenols and the Case for Physical Demulsification

Coal Tar Hydrogenation Sour Water: Acidity, Phenols and the Case for Physical Demulsification

2026-11-23 3 readings

Coal tar hydrogenation exists to upgrade something difficult into something saleable: the complex organics in coal tar are pushed through hydrogenation reactions until they resemble conventional oil products. An aqueous phase comes along for the ride, and that phase is what the wastewater plant inherits.

Calling it sour water is accurate but incomplete. It is acidic, it is phenolic, it is oily, and its quality moves with the feedstock. A train designed for one of those properties will fail on the other three.

Property one: acidity that attacks the pipework

Hydrogen sulphide, carbon dioxide and phenolic compounds all arrive together, and together they push pH down and corrosivity up. Hydrogen sulphide ionises in water and releases hydrogen ions, following the familiar equilibrium H2S ⇌ H+ + HS-, so the acidity is not a fixed inventory but a shifting one that responds to temperature, pressure and how much gas has already flashed off.

Practically, that means carbon steel is a consumable. It also means the treatment line has to be arranged so that the corrosive fraction is removed early rather than carried through several vessels before anyone deals with it.

Property two: organics that biology refuses

Phenols and polycyclic aromatic hydrocarbons dominate the organic load. Both are toxic to activated sludge at concentrations well below the values seen in this stream, and both are poorly biodegradable even after acclimatisation. The hydroxyl group (-OH) in the phenol structure is what gives the molecule its mild acidity and much of its toxicity to living organisms.

The implication for design is blunt: a biological stage placed early in the line will be poisoned, and one placed late will be asked to polish a stream that has already passed through several physical steps. Either way, the organics are removed by oxidation or by separation, not by bugs.

Property three: oil in emulsion form

Oily matter in coal tar sour water does not float as a layer. It forms emulsions, and those emulsions are what make downstream equipment behave badly. In flotation, oil coats the bubble release devices and cuts the effective gas transfer. In filtration, it blinds media and raises differential pressure within hours. Neither failure is dramatic, which is why both are usually discovered through cost rather than through alarm.

Property four: quality that follows the feedstock

Change the source of the coal tar, or shift the temperature and pressure of the hydrogenation reactor, and the pollutant types and concentrations in the sour water change with them. A process that depends on a fixed coagulant dose or a fixed residence time will be chasing the plant forever. What the line needs is shock resistance and a physical mechanism that does not care what the surfactant of the week happens to be.

Running the stream through four vessels and a stripper

SINOKLE has built the treatment line around its own product portfolio, with CDFU and KHC as the working pair. Sour water passes coarse filter A/B first, then the CDFU, then fine filter A/B, then the KHC coalescing oil separator, and only after that does it reach the stripper unit.

The order is deliberate. Coarse filtration takes out the material that would damage the flotation internals. CDFU removes the bulk of the oil and suspended solids using cyclonic dissolved gas flotation, so the fine filters are not asked to hold what flotation should have caught. The KHC unit then polishes the oil that remains. By the time the water reaches the stripper, it is a water problem rather than an emulsion problem.

The two units doing the real work

CDFU is a vertical-tank flotation unit built on cyclonic dissolved gas flotation. It combines cyclonic centrifugal separation, ultrafine bubble generation and dissolved gas flotation in a single shell, and that combination is what allows it to separate oily sludge, emulsified oil and suspended solids quickly rather than over a long residence time. Vertical geometry keeps the footprint small, which is why the unit fits inside existing battery limits.

The KHC coalescing oil separator uses a super-oleophilic, hydrophobic coalescing fibre and an optimised internal flow path. Cyclone centrifugation, wetting coalescence, collision coalescence and interception filtration are integrated in one vessel, so emulsified oil is grown into droplets, separated and removed in sequence rather than in separate stages with pumps between them.

What the operator actually gets

  • No chemical dosing. Demulsification and separation are physical, so there is no coagulant inventory, no dosing pumps to maintain and no dose to re-tune when the feedstock changes.
  • No scum and no oily sludge. The usual secondary waste of a chemical route simply is not generated, which removes a disposal contract and its associated risk.
  • Recoverable oil. Separated oily sludge comes off with good quality and low water content, so it can go back for reprocessing instead of to a burner.
  • Stable demulsification. Because separation does not rely on chemistry that can be overwhelmed, performance holds across the quality swings described above.

Coal tar hydrogenation is one of the streams where a chemical answer looks cheapest at the quotation stage and turns out most expensive at the third year of operation. The physical answer costs more upfront and then stops generating problems.