Coal Chemical RO Concentrate: Taking COD From 500 to 60 mg/L Without Biology

2026-11-23 2 readings

Coal chemical plants generate wastewater from several directions at once: gas scrubbing, blowdown from circulating water systems, blowdown from the demineralised water plant. The volumes are large and the compositions are messy. To reuse the water or simply discharge it legally, plants pre-treat first — coagulation and sedimentation for solids and colloids, pH adjustment, sodium hypochlorite to keep microbiology under control — and then push the clarified water through reverse osmosis membranes.

The membranes do their job. What they leave behind is the problem: a concentrate that is saline, strongly coloured and rich in organics that survived both the pre-treatment and the membrane.

What makes this concentrate different from a cooling tower blowdown

  • Salt. Conductivity is high enough to corrode downstream equipment and to make any biological step pointless, because the biology is inhibited long before it is stressed.
  • Colour and organics. The dark tint is not dye. It is phenols, alcohols, benzenes, aromatic hydrocarbons and fatty acids, most of them bio-refractory, which is why organic concentration stays high after every conventional step.
  • Mixed composition. Heavy metal ions and ammonia nitrogen appear alongside the organics, so a single targeted process cannot cover the stream.
  • Load shock. When concentrate is returned to the front of the plant, downstream units see a COD spike that destabilises their own biology and pushes the whole works toward non-compliance.

Why the usual four answers only move the problem

Reflux to the inlet is the cheapest option and the most expensive in the long run: it raises the salt load on the membranes, accelerates wear and shortens element life, which turns an operating decision into a capital one.

Coagulation and adsorption target colloids and suspended solids. They work, but their performance depends on water quality and pH, so the dose that succeeds in January fails in July when the feedstock changes.

Activated carbon removes COD effectively until the carbon is spent. Regeneration or replacement then becomes a recurring line item, and spent carbon is its own disposal problem.

Advanced oxidation on its own improves COD, colour and biodegradability significantly, yet the ozone utilisation of a simple contact column is low enough that the cost per kilogram of COD removed stays high. Each of these four addresses a symptom.

Coagulation first, then ozone in the same vessel as the flotation

SINOKLE approaches the stream with a combined process built around CDOF, the integrated advanced ozone oxidation flotation unit. Coagulant and flocculant go into the concentrate first; after sedimentation, part of the suspended and colloidal load drops out and the downstream oxidation has less material to attack.

The water then enters the CDOF unit, where ozone from the generator does the chemistry. Ozone oxidises large molecules into smaller ones, which lowers COD, and it breaks the chromophore structures that produce colour. The flotation side of the unit separates the oxidised impurities and fine particles and lifts them out with the backwash water, so the reaction products do not simply stay in solution waiting to recombine.

Two things happen at once in that vessel and that is the point. Oxidation without separation leaves the oxidised fragments in the water. Separation without oxidation cannot touch dissolved organics. Running both in one shell also keeps the ozone in contact with a freshly coagulated stream, which is where the radical chain starts most readily.

Numbers from a working 50 m³/h unit

At a project site, concentrate entering the train at or below 500 mg/L COD leaves below 60 mg/L. Colour drops from a reading of 200 or less to under 30. Both figures hold across feedstock changes that would have shifted a coagulation-only process by a factor of two.

Operating cost for the complete 50 m³/h train comes in at 10 RMB or less per tonne of water treated. That figure includes power for the ozone generator, which is the dominant term, and it is what makes the process defensible to a plant accountant rather than only to an environmental engineer.

The two failure modes worth designing against

The first is under-dosing coagulant to save money. Concentrate carries colloids that consume ozone on contact, so a starved coagulation step shows up as an ozone bill rather than as a clarity problem. The second is running the unit at low load for long periods. Ozone output turns down, contact time stretches, and the flotation cells stop producing the bubble density the design relies on, which leaves oxidised fragments in the water. Both are operating habits, not equipment faults, and both are solved by trending COD across the unit rather than only at the outlet.

Where the process fits and where it does not

This is a concentrate treatment, not a substitute for the reverse osmosis train that produced it. It suits plants that already recycle water and now need the reject stream to stop being a liability, and it suits plants whose discharge permit is written around COD and colour rather than around salt. Where the binding constraint is salinity alone, evaporation and crystallisation remain the only real answers and ozone will not help.

What the CDOF route does deliver is a concentrate that can go back into the plant or out of the gate without a dilution credit. For a coal chemical complex where water reuse is already the operating philosophy, that closes the loop the membranes opened.