Ternary Precursor Product Liquid: Removing Oil and TOC Without Touching Purity
The hidden cost of carbon and resin
Ternary precursor product liquid is a key material in the new energy field, and the high concentrations of oil and total organic carbon (TOC) it carries pose major challenges both to downstream product performance and to subsequent treatment. The conventional answer is adsorption, and it comes with four defects that compound.
- High material cost. Coconut-shell activated carbon and special resins are required, and raw material costs are high.
- Hazardous waste. Saturated activated carbon becomes hazardous waste, and outsourced disposal adds operating cost on top of the purchase price.
- Cumbersome operation. Activated carbon must be replaced every two days, which relies on manual attendance and interrupts an otherwise continuous line.
- Safety exposure. Ethanol is used for resin regeneration, which introduces a flammable solvent into the plant.
Read together, these four points describe a process that removes oil by converting it into a disposal problem, every second day, with a solvent hazard attached.
What CDOF changes
SINOKLE Technology developed an integrated ozone flotation device, CDOF, which combines three core technologies: ozone catalytic oxidation, hydraulic cyclonic separation and flotation deoiling. A self-developed acid-resistant modified heterogeneous ozone catalyst sits inside it. The combination achieves efficient oil removal and TOC reduction while ensuring that the ionic composition and purity of the product liquid are not affected, which is the constraint that rules out most wet chemical approaches.
The mechanism explains the fit. Ozone catalytic oxidation attacks dissolved oil and organic carbon; cyclonic separation and flotation lift the freed droplets and solids out of the liquid phase. Because the oxidant is generated on site and destroyed in the unit, no reagent residue enters the product stream.
Performance data
Experimental verification gives two figures that matter commercially. Oil content, including dissolved oil, is reduced to 2 ppm or below. TOC removal sits stably at or above 60%. Both are sustained figures rather than a single best run, which is the difference between a laboratory result and a process guarantee.
Side by side with the conventional route
The comparison is best made on four dimensions rather than one. On treatment effect, TOC removal exceeds 60% against the limited TOC capacity of adsorption. On operating cost, the integrated process runs at 1/3 to 1/2 of conventional processes, and the difference widens once hazardous waste disposal is counted; the comparison table in the original assessment puts the reduction at 50%-67%. On maintenance frequency, the catalyst does not need frequent replacement while activated carbon is replaced every two days. On safety and environment, the unit is fully enclosed with no leakage and no hazardous waste output, against ethanol use and hazardous waste generation.
Purity, and why it is the hard constraint
For a battery material, removing oil is easy and removing oil without shifting the ionic balance is not. Every additive, pH swing and rinse step risks contaminating the product liquid, and the acid-resistant catalyst was developed specifically so that metal contamination does not enter the stream. Zero secondary pollution follows the same logic: no chemicals are added anywhere in the process, so there is no reagent to rinse out and no new impurity to certify.
Where the unit sits in the line
Placement matters as much as performance. The unit works best immediately upstream of the step that is sensitive to organics, so that oil and TOC are removed before they can foul resin, membrane or crystalliser surfaces. Feeding it after a holding tank gives steadier composition and lets the plant smooth out batch discharges; feeding it directly off the reactor shortens residence time but exposes the catalyst to temperature and pH swings. Most installations take the middle route, with a small buffer tank sized on one batch rather than on a day of production.
What to put in the specification
Four items do most of the work in a tender. State the oil and TOC limits at the unit outlet and the analytical method used to measure them, because dissolved oil is easy to leave out of a contract. State the permitted change in ionic composition and conductivity across the unit. State the catalyst service life expected under the actual feed, with a replacement cost written in. And state the availability expectation, since a unit that needs an unplanned stop every few weeks delivers none of the operating benefit that justified it.
Operating characteristics worth knowing
Residence time is short and the footprint small, so the unit fits into an existing battery-material plant without a new building. Enclosed pressurised operation eliminates ozone leakage, which addresses the main safety objection to ozone in a clean production environment. Operation and maintenance are fully automatic with remote monitoring support, requiring no attendance, and China's first triple-technology linkage system gives the package its process margin. For a line that previously stopped every two days to change carbon, the operational change is the selling point as much as the water quality.