Home News Knowledges Oily Wastewater at Heavy-Oil Power Stations: Small Flows, Stubborn Emulsions

Oily Wastewater at Heavy-Oil Power Stations: Small Flows, Stubborn Emulsions

2026-11-18 13 readings

Why heavy-oil plants are awkward

Heavy-oil power plants generate electricity with heavy oil as fuel. Beyond exhaust pollution, operation produces oily wastewater from oil tank cleaning, pipeline leaks, equipment washing, and lubricating oil mixed in from the coal handling system. The composition is complex and treatment is difficult for three reasons that reinforce each other: heavy oil coexists with light oil, the small treatment volume rules out high-efficiency regeneration technologies that only pay at scale, and emulsified oil makes natural settling ineffective. Oil content may not be high, but discharging it untreated would severely damage the downstream sewage treatment system.

Three conventional routes and where each one fails

Composite settling tank plus high-clarity filter. Relies on chemicals for settling. It has a large footprint, high cost and low automation, needs manual sludge removal, and carries safety and environmental risk.

Oil separation tank plus flotation tank plus filtration. Conventional flotation gives unstable removal of emulsified oil and of high-density oil droplets, and easily clogs filters. The footprint and cost problems remain.

Oil-water separator. Because oil and water densities are close, gravity separation is inefficient and poorly resistant to fluctuation. The equipment occupies a large footprint, the packing clogs easily and performance falls short of what discharge limits now require.

The common thread is that all three rely on density difference, and heavy oil blurs that difference. Small flow makes it worse: there is no economy of scale to absorb a complex train.

A CDFU-centred process

To address these problems, SINOKLE adopted a technology centred on CDFU cyclonic dissolved air flotation, forming a complete process for heavy-oil power plant oily wastewater. The unit generates microbubbles and combines them with a cyclone field, so separation does not depend on the oil being much lighter than the water. Emulsified droplets attach to bubbles, and the cyclone amplifies the effective density difference, which is exactly what a heavy and light oil mixture defeats in a gravity separator.

Field evidence

The scheme has been applied at the Sierra Leone heavy-oil power station, with total installed capacity of 43.65 MW. The wastewater there features high heavy-oil density, high viscosity and severe emulsification; through two-stage CDFU units, oils and suspended solids are effectively removed, treating oily wastewater from the main power house, oil pump house and tank farm to ensure compliant discharge. A Bangladesh fuel power station project commissioned in 2021 verified the reliability of the same process under different crude and different operating patterns.

Two sites is not a statistical population, and it would be dishonest to present it as one. What the two projects do establish is that the process tolerates the two variables that most often break pilot-scale promises: oil density and emulsion severity.

What the skid design changes for operators

Removal of oil and suspended solids is significant and shock resistance is strong, so effluent stays compliant through washdown peaks. The flow sheet is short and mainly physical, which means little oily sludge and low operating cost. Skid mounting keeps the package compact and light, cutting the footprint that constrained every conventional option, and automated control reduces the intensity of manual operation. Because the process is verified by projects at home and abroad, operational risk at start-up is lower than for a first-of-a-kind train.

Materials, because heavy oil comes with salt and sulphur

Heavy-oil stations rarely present clean oily water. Washdown carries salt from tank bottoms, and heavy fuel brings sulphur compounds that turn aggressive once the water is aerated. Wetted parts therefore deserve as much attention in the specification as removal efficiency does. Stainless wetted surfaces, a cyclone lined for abrasive service and a skid frame that survives a coastal atmosphere cost a fraction of a mid-life replacement, and they matter more at a small plant where there is no standby unit. Ask for the material schedule, not just the flow sheet.

What the operating data should show

Commissioning should leave behind three curves rather than three numbers: effluent oil content against influent oil content, differential pressure against throughput, and recovered oil volume per washdown cycle. Those three curves tell an operator whether the unit is drifting before the discharge sample does, and they make the case for planned maintenance instead of reactive cleaning. Where the station logs them monthly, the unit tends to stay inside its design envelope for years; where it does not, the first sign of trouble is usually a permit exceedance.

Selection notes

Size on the peak washdown rate rather than the monthly average, because that peak sets the unit. Confirm the sludge route before ordering: the float from flotation still needs handling, even though the volume is small compared with chemical settling. And check whether two-stage CDFU is genuinely required or whether a single stage plus polishing meets the local limit, since the second stage is where most of the cost sits.