Cogeneration Oily Wastewater: Holding the 5 mg/L Limit With a KHC Deoiler
A cogeneration plant is judged on megawatt-hours, but its environmental compliance often turns on a few cubic metres a day of oily water. That water comes from lubricating oil leakage around equipment, from treatment of fuel combustion off-gas, and from pipeline flushing. All three carry emulsified oil, suspended solids and organic pollutants, and all three go to drain if nothing intercepts them.
Why This Stream Is Harder Than It Looks
The oil is not one substance. Free oil, dispersed oil, emulsified oil and dissolved oil are all present, and each responds to a different mechanism. Gravity separation handles the first two well enough and then stops, because the emulsified fraction will not rise at a useful rate no matter how long the retention time. Dissolved oil does not separate at all; it has to be oxidised or adsorbed. A process designed only for free oil therefore passes most of the load straight through.
Flow and concentration swing with production load, so a unit sized for average conditions is either oversized at night or overloaded at peak. And the discharge requirement is unforgiving: the oil concentration must meet the limit of no more than 5 mg/L set by the Integrated Wastewater Discharge Standard. Five milligrams per litre is close enough to the detection limit that a visible sheen on the outfall is already a violation.
The Arrangement: Filter First, Then Coalesce
To solve the problem, SINOKLE developed a treatment process built around the KHC coalescing pressure deoiler as the core unit, with a customised filter ahead of it. The order matters. Oily wastewater first passes through the filter, which removes suspended solids and residue, and then enters the high-efficiency deoiler for oil-water separation. Solids removed early cannot blind the coalescing packing, and the packing is where the actual oil removal happens.
After practice on several projects, the treated effluent has been tested and consistently meets the standard, achieving the expected treatment performance and effectively solving the oily wastewater problem at the cogeneration project. The effluent is clear and bright — a useful field indicator, since a coalescer that is working produces water that looks like water, while one that is bypassing or blinded produces a faint haze that instruments may or may not catch.
Inside the Deoiler
The high-efficiency coalescing pressure deoiler is the patented core of the system. It is based on the coalescence principle and shallow-pool theory, and uses CFD numerical simulation to optimise tank space and structure systematically. By scientifically planning the internal flow field, it achieves efficient aggregation, coalescence, flotation or settling, and separation of oil droplets and suspended solids in the aqueous phase.
The equipment uses a three-stage separation architecture: a cyclone separation device in the inlet pre-separation zone, gradient coalescing packing in the primary and main separation zones, an integrated oil collection unit at the top and an intelligent sand-washing and sludge-removal system at the bottom. Together these form a complete separation chain, from bulk removal at the inlet to polishing in the main zone to continuous sludge handling at the bottom — rather than a single chamber asked to do all three jobs at once.
Four Design Choices Worth Noting
- Integrated design: the compact structure saves 60% of floor space and oil removal efficiency exceeds the 90% technical threshold, which matters in a plant where the water treatment area was an afterthought.
- Material innovation: the patented coalescing packing uses high-strength stainless steel or reinforced polypropylene, combining mechanical properties with durability under pressure and thermal cycling.
- Anti-clogging assurance: a proprietary vortex sand-washing device performs dynamic desilting, keeping the open ratio of the packing layer above 95% over the long term, so performance does not decay toward the next maintenance window.
- Intelligent operation: fully enclosed pressure-type automatic control with zero leakage risk in operation, and safety and environmental indicators that meet national standards.
Field Evidence
Verified in engineering projects covering refining wastewater and power-plant circulating water, the process shows outstanding stability and adaptability: under continuous operation for more than 8,000 hours the oil content of the effluent remains within the standard. Long-run data of that kind is more persuasive than a commissioning test, because the usual failure mode of coalescing equipment is gradual — packing gradually blinded, efficiency drifting from 90% to 70% over a year and nobody noticing until a sample is taken.
Its technical universality now covers oily wastewater treatment in the energy, chemical and power industries, which is the practical argument for standardising on one platform: the same architecture, resized, serves streams that the plant currently treats with three different and separately maintained systems.
Sizing Advice
Two mistakes recur. Sizing on average flow instead of peak leaves the unit unable to hold 5 mg/L during load swings, since coalescence is residence-time dependent. Sizing without solids data sends coke fines or mill scale into the packing, where the sand-washing system can slow the loss but not prevent it. Get the filter duty right and the deoiler will hold its numbers; get it wrong and no amount of packing volume compensates.